Specialized Testing



FRA Rules That Apply

Satisfy Requirements of FRA Signal Rules With Our Test Equipment
Rule # Rule Description S & C Equipment
236.109 Time Releases, Timing Relays, Devices Model 410 Test Timer
236.382 Switch Obstruction Test Model 236-382


Shortcut to Specific Products


410 Signal Test Timer

The Model 410 Signal Test Timer has several capabilities that address various operations and signal related needs.

  1. Portable. Operates on furnished, plug-in 120VAC to 12VDC power supply or local battery, or Battery Kit accessories. Can also be installed on a permanent basis.
  2. Data from tests is recorded and can be downloaded. Download is implemented with the use of HyperTerminal (r), a program provided with Windows(r) operating system, or other standard communication program, through a USB port. Complete instructions for downloading, the printing of reports, etc., are provided in the Instruction Manual for the Model 410 Signal Test Timer.
  3. Determines Train Speed (PN: 410-18 Train Speed Transducer Kit and PN: 330-23T Battery Kit or 330-24 Battery Kit req'd) - install Train Detector Transducers on same rail, 100 feet apart. Connect cables to the Train Detector Transducers and the Timer Speed Interface. Attach power source (Battery Kit, etc.) to the Timer. Connect Timer Speed Interface to the Timer and wait for trains to pass. The installation process takes approximately thirty minutes to complete, once access to the track has been granted by the dispatcher. See hook-up diagram below.
  4. Determines Activation Lag & Throw Times of Switch Machines - Dry set of contacts from switch machine normal and reverse indications are connected to the Form C Inputs and normal and reverse voltages from the switch machine control point are applied to the Automatic Inputs.
  5. Determines Code Relay Rates - connect front and back contact of code relay to Form C Inputs.
  6. Determines Transition Times of Searchlight Signals - Connect normal and reverse contacts of searchlight signal to Form C Inputs
  7. Determines Activation Times of Solenoids equipped with contacts.
Typical field hook-up.


Specifications

Accuracy: +/- 0.001 Seconds
Input Voltage: 10-16VAC or VDC (must match relay under test)
Operating Current: Minimum 60mA AC or DC, and will depend on relay load
Coil Output Voltage: Varies with and is less than input voltage depending on coil value.
Sense Input Isolation: Opto Coupler
Environmental Operating Temperature Range:
LCD Display: +15 deg. to +160 deg. F
Timer Functions: -40 deg. F to +160 deg. F

Timer Messages Displayed on LCD Screen:

Code Relay:
Code Rate
Period in Milliseconds
On Time Percentage
Off Time Percentage

Normal or Time Delay Relays:
Time Pick
Time Drop

Automatic Mode:
Activation Lag Times
Normal Throw Time
Reverse Throw Time

Speed Mode:
Speed in Miles Per Hour or Kilometers Per Hour (user selected)
Speed in Feet Per Second or Meters Per Second (user selected)

ORDERING REFERENCES
Description Part Number
Model 410 Signal Test Timer, w/padded case, 500mA DC Power Supply & six 8 ft leads 410-1
Train Speed Transducer Kit (includes 2 transducers, Timer Speed Interface, Cable with Spools and Full-Kit Carry Cases 410-18
Battery Kit, 1.2AH w/Charger, to mount in padded case of Timer 330-24
Battery Pack, 3.0AH, w/Charger, Carrying Case & Connector 330-23T
Carry Case (HD canvas for Timer and 3.0AH Battery Kit 506BZB

410-2 Train Speed Timer

The Model 410 Train Speed Timer allows the user to time trains, record the data, then download the recorded information on to a computer for analysis and other purposes. See below for a typical field hook-up.
  1. Portable. Operates on furnished, plug-in 120VAC to 12VDC power supply or local battery, or Battery Kit accessories. Can also be installed on a permanent basis.
  2. Determines Train Speed (PN: 410-18 Train Speed Transducer Kit and PN: 330-10T Battery Kit or 330-24 Battery Kit req'd) - install Train Detector Transducers on same rail, 100 feet apart. Connect cables to the Train Detector Transducers and the Timer Speed Interface. Attach power source (Battery Kit, etc.) to the Timer. Connect Timer Speed Interface to the Timer and wait for trains to pass. Data collected is downloadable. The instalation process takes approximately thirty minutes to complete, once access to the track has been granted by the dispatcher.
  3. Download operation is implemented with the use of HyperTerminal (r), a program provided with Microsoft Office (r), or other standard communcation program. Complete instructions for downloading, the printing of reports, etc., are provided in the Instruction Manual for the Model 410 Train Timer.
Typical field hook-up.


Specifications

Accuracy: +/- 0.001 Seconds
Input Voltage: 10-16VAC or VDC
Operating Current: Minimum 60mA AC or DC
Coil Output Voltage: Varies with and is less than input voltage depending on coil value.
Sense Input Isolation: Opto Coupler
Environmental Operating Temperature Range:
LCD Display: +15 deg. to +160 deg. F
Timer Functions: -40 deg. F to +160 deg. F

Timer Messages Displayed on LCD Screen:

Speed Mode:
Speed in Miles Per Hour or Kilometers Per Hour (user selected)
Speed in Feet Per Second or Meters Per Second (user selected)

ORDERING REFERENCES
Description Part Number
Model 410 Portable Train Speed Timer, w/padded case, 500mA DC Power Supply & 410-18 Transducer Kit 410-2
Train Speed Transducer Kit (included 2 transducers, Timer Speed Interface, Cable with Spools and Full-Kit Carry Case) 410-18
Battery Kit, 1.2AH w/Charger, to mount in padded case of Timer 330-24
Battery Pack, 7.0AH, w/Charger, Carrying Case & Connector 330-10T
Timer and 7.0AH Battery Kit Carry Case (HD canvas) 506BZB

Model 322 Shunt and Coupler Tester

Download PDF File
The widespread use of motion sensing and constant warning time track circuits has resulted in the proliferation of wide and narrow band shunts and IJ couplers. Many times the circuits are overlapped, resulting in ever-increasing problems of turning and frequency conflict. The troubleshooter needs to know the complete range of characteristics of the shunts and couplers with which he is dealing, when attempting to identify the source of circuit malfunctions.

This device permits the signalman to know the frequencies, tuning characteristics, attenuation and thru-put capacities of each device in the approach "network", empowering him to relatively quickly determine the source of the problem.

  1. Identify center frequencies of shunts, couplers and related transmitters
  2. Determine termination and signal thru-put capacities
  3. With data from tester, rule out shunts as sources of tail ring
  4. Adjust turnable couplers and shunts prior to installation
  5. Test for DC leakage
  6. Frequency range: 10HZ to 5120HZ
  7. For field or shop use
  8. Operates on rechargable, 12VDC, 1.2AH lead acid battery


Application
This highly portable device permits the maintainer to bridge or terminate signals into the shunts or couplers under test. It can be moved to the area of the track where the shunts or couplers are in service, maximizing effectiveness and minimizing time required to perform the tests.

"Sweep" Function automatically checks full range for tuning points. Graphic display pictorially shows frequency curve and tuning points.

Seperate inputs for Tuning, Leakage and Frequency Meter Tests reduce potential for resistance in switch contacts to adversely affect test results.

ORDERING REFERENCES
Description Part Number
322 Tester with 12V rechargeable battery, DC to DC Charger, Leads, Carrying Case 322-1
ACCESSORIES FURNISHED
In-Vehicle Charging Adapter 324-12
DC to DC Charger for in-bungalow use 324-21
Lead Set, 4 ft., HD Clips 322-15
OPTIONAL ACCESSORIES
110VAC to 12VDC Charger 324-11

Model 236-382 Obstruction Gauge

Obstruction Gauges are used to comply with FRA required tests of track switches. They are used to determine if a power operated switch or a hand operated switch and lock movement has been adjusted properly. Proper adjustment is deemed to occur when the switch cannot be locked up when the appropriately sized obstruction is placed between the switch point and stock rail, six inches from the end of the switch point.

The design concept S&C Distribution Company has employed provides four gap gauges of standard values and in combinations that enable fast change over to values used for different tests. The design also assures more stable, self-retaining mounting to the rail during tests.

Gauge No. 236-382B (Dwg. To the left) offers the gap gauges most common to signal testing (AREMA standard). Gauge No. 236-382A provides a 5/16th inch gap gauge that addresses special adjustment to M-23 Switch Machines where the practice of floating off the lock rods occurs. At locations where a split point derail is operated with a switch machine or a hand operated switch and lock movement, we offer a special gauge, No. 236-382C, where a ½ inch gap gauge is provided.

ORDERING REFERENCES
Description Part Number
Switch Obstruction Gauge with 3/16, 1/4, 5/16 and 3/8 Gap Gauges
Side 1 with 3/16 & 5/16 in Gaps and side 2 with 1/4 and 3/8 in Gaps
236-382A
Switch Obstruction Gauge with 1/8, 3/16, 1/4 and 3/8 in Gap Gauges
Side 1 with 1/8 and 1/4 in. Gaps and side 2 with 3/16 and 3/8 in. Gaps
236-382B
Switch Obstruction Gauge with 3/16, 1/4, 3/8 and 1/2 in. Gap Gauges
Side 1 with 3/16 and 3/8 in. Gaps and Side 2 with 1/4 and 1/2 in. Gaps
236-382C